Construction Quality Award 2017: Interior Plaster

AWCI's Excellence in Construction Quality Award 2017


Category: Interior Plaster


Winning Project: Santa Rosa Chapel at Children’s Hospital of San Antonio (San Antonio, Texas)


Total Man-Hours — 2,500

Total Square Footage — 55,000


Materials Used

Substrate — 20,000 sf

Acoustical Plaster — 20,000 sf

Acoustical Panels — 20,000 sf

Trim — 3,600 lf

Access Platforms — 10,500 sf


Challenge Accepted

MK Marlow Company, LLC teamed with the GC and steel manufacturer to merge information from four different models generated in four different software environments into CAD where they designed the framing solution in 3D and CNC fabricated CFS profiles from that model.


Once the single layer roll bended steel frame was complete, light gauge metal framing was modeled in 3D to infill the red iron, provide the varying wall thicknesses, and control the compound curving geometry.


CNC fabricated studs fit into custom angle as infill between red iron at thin wall areas. As the wall thickness increased, the angle offset increased until it could bypass the red iron and was able to span continuous from the curved floor track to the top track. Over the light gauge framing are multiple layers of 1/4-inch flex board and an acoustical plaster system.

Browse Similar Articles

You May Also Like

As design trends evolve, the ceiling is gaining recognition as a crucial element in creating a cohesive and impactful interior space.
Stark bidding is very competitive now and owners seem a little weary of getting things started here in California due to the state of the economy and the federal election.
AWCI's Construction Dimensions cover

Renew or Subscribe Today!